Accessories Installation
50
Air-to-Water Heat Pump
To establish sanitary water circuit, 3way valve and sanitary water tank kit is required. If solar thermal
system is pre-installed at the installation field, solar thermal kit is required to interface solar thermal
system - to - sanitary water tank - to - .
Installation condition
Installing sanitary water tank requires following considerations :
• Sanitary water tank should be located at the flat place.
• Water quality should be complied with EN 98/83 EC directives.
• As this water tank is sanitary water tank (indirect heat exchange), do not use anti water-freezing
treatment like ethylene grycol.
• It is highly recommend to wash out inside of the sanitary water tank after installation. It ensures
generating clean hot water.
• Near the sanitary water tank there should be water supply and water drain to easy access and
maintenance.
• Set the maximum value of the temperature control device of sanitary tank.
Sanitary
Water Tank
Water Tank Sensor
Water In
Water Out
Sanitary Water Tank and Sanitary Water Tank Kit