System Set-Up
66
Air-to-Water Heat Pump
Code
Item
Detail
Remark
12
Value #2
Note
Lower limit of setting range(FCU is not equipped)
Default
16 °C
Range
16 ~ 18 °C
13
Function
Setting air temperature in heating mode
Description
Adjusting range of 'Setting Air Temperature' in heating mode
Value #1
Note
Upper Limit of setting range
Default
30 °C
Range
24 ~ 30 °C
Value #2
Note
Lower Limit of setting range
Default
16 °C
Range
16 ~ 22 °C
14
Function
Setting leaving water temperature in heating mode
Description
Adjustin range of 'Setting Leaving Water Temperature' in
heating mode
Value #1
Note
Upper Limit of setting range
Default
55 °C
Range
35 ~ 57 °C
Value #2
Note
Lower Limit of setting range
Default
15 °C (*20 °C)
Range
15 ~ 34 °C (*20 ~ 34 °C)
15
Function
Setting sanitary tank leaving water temperature for
Sanitary water heating
Description
Adjusting range of 'Setting Sanitary Tank Leaving Water Temperature'
in sanitary water heating mode
Value #1
Note
Upper Limit of setting range
Default
50 °C
Range
50 ~ 80 °C
Value #2
Note
Lower Limit of setting range
Default
40 °C
Range
30 ~ 40 °C
18
Function
Screed drying mode
Description
After installing water pipes for under floor heating, user can select
screed drying mode for curing the cement
Value #1
Note
Default
01
Range
00 ~ 01
Value #2
Note
Default
-
-
Range
-
'Setting Air
Temperature' is
used when user
wants to set target
temperature by
room air
temperature.
'Setting Leaving
Water
Temperature' is
used when user
wants to set target
temperature by
leaving(from the
unit) water
temperature.
* : Electric heater
is not used
'Setting Sanitary
Tank Leaving
Water
Temperature' is
used when user
wants to set water
temperature of
Sanitary Tank.
00: Screed drying mode is not connected and not used.
01:Remote air sensor is connected and used.