System Set-Up
68
Air-to-Water Heat Pump
Code
Item
Detail
Remark
Note
Starting date (Sunday:1,Monday:2, ···· ,Saturday:7)
Default
06
Range
01 ~ 07
Value #2
Value #1
Note
Starting time in 24 hours(00 ~ 23)
Default
23
Range
00 ~ 23
27
Function
Setting Disinfection Operation
Description
Setting disinfection temperature
Value #1
Note
Maximum heating temperature
Default
70 °C
Range
40 ~ 80 °C
Value #2
Note
Maximum heating duration in minute
Default
10 min
Range
05 ~ 60 min
28
Function
Setting control parameter for sanitary water heating operation
Description
See below notes for each values
Value #1
Note
Temperature gap from Value #2 of Function Code 28
Default
05 °C
Range
01 ~ 20 °C
Value #2
Note
Maximum temperature generated by AWHP compressor cycle
Default
55 °C
Range
40 ~ 57 °C
29
Function
Setting control parameter for sanitary water heating operation
Description
See below notes for each values
Value #1
Note
Temperature gap from target sanitary water temperature.
(This value is required to frequent ON and OFF of water tank heater.)
Default
03 °C
Range
02 ~ 04 °C
Value #2
Note
Determining heating demand priority between sanitary water tank
heating and under floor heating
Default
00
Range
00 ~ 01
Only available
when Sanitary
Water Tank is
installed.
the disinfection
mode will not be
operated although
Value #1 of Code
26 is set as '01'.
• To use
disinfection mode,
sanitary water
heating should be
enable.
25
Function
Setting leaving water temperature range for weather-dependent operation
Description
Setting leaving water max / min temperature fo
r
weather-dependent operation
Value #1
Note
Upper limit of setting range
Default
55 °C
Range
35 ~ 57 °C
Value #2
Note
Lower limit of setting range
Default
15 °C (*20 °C)
Range
15 ~ 34 °C (*20 ~ 34 °C)
26
Function
Setting disinfection operation
Description
Setting start/maintain time for disinfection
Value #1
Note
Enable / Disable of disinfection operation(00:Disable , 01:Enable)
Default
00
Range
00 ~ 01
Sanitary water
* : Electric heater
is not used
heating should be
enable.
• If sanitary water
heating is disable,