54
ENG
ENGLISH
EXTERNAL CONTROL DEVICE SETUP
29. Elapsed time return (Command: d l)
To read the elapsed time.
Transmission
[d][l][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[l][ ][Set ID][ ][OK/NG][Data][x]
* The data is always FF(in Hex).
(Hexadecimal code)
30. Temperature value (Command: d n)
To read the inside temperature value.
Transmission
[d][n][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
31. Lamp fault Check (Command: d p)
To check lamp fault.
Transmission
[d][p][ ][Set ID][ ][Data][x]
* The data is always FF(in Hex).
Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]
* The data is 1 byte long in Hexadecimal.
Data 00 : Lamp Fault
01 : Lamp Ok
02 : N/A (DPM/Power Off)
32. Auto volume (Command: d u)
Automatically adjust the volume level.
Transmission
[d][u][ ][Set ID][ ][Data][x]
Data 00: Off
Data 01: On
Acknowledgement
[u][ ][Set ID][ ][OK/NG][Data][x]
33. Speaker (Command: d v)
Turn the speaker on or off.
Transmission
[d][v][ ][Set ID][ ][Data][x]
Data 00: Off
Data 01: On
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x
34. Time (Command: f a)
Set the current time.
Transmission
[f][a][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]
[Data1]
00 : Monday
01 : Tuesday
02 : Wednesday
03 : Thursday
04 : Friday
05 : Saturday
06 : Sunday
[Data2]
0H to 17H (Hours)
[Data3]
00H to 3BH (Minutes)
Acknowledgement
[a][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
*When reading data, FFH is inputted for [Data1],
[Data2] and [Data3]. In other cases, all are treated as
NG.