74
Symptom
Possible Cause
Possible Solution
Inability to compact materials to
tablet form
The Fill Tray is blocked and not
enough materials are flowing out.
Check the Fill Tray for a potential
clog.
There is not enough pressure.
Rotate the Pressure Knob on
the lefthand side of the machine
clockwise.
The Tooling is damaged.
Remove and replace the Tooling (all
Upper Punches, Lower Punches, and
Dies)
There are flowing issues with the mix.
If the machine is able to make tablets
with LFA's Firmapress®, then the
problem is your mix. Adjust your
formulation. If still an issue, contact
LFA for support.