Diagnostic Information
2-15
4044-XXX
Model E310
Engine/LVPS Board
Power Switch
Disconnect the cables from CN2 and
CN5 and leave the cables connected
to the power switch attached. With
the printer positioned on its left side
and the engine/LVPS board
positioned on a flat surface, turn the
power switch on and check the AC
line voltage at connector CN201. If
no voltage is present, replace the
power switch. If line voltage is
present, measure the voltages at
connectors CN2 and CN5. Go to
the
“Engine/LVPS Board (model
E310)” on page 5-4
and check for
correct voltage measurements.
Replace the engine/LVPS board if
any of the voltage measurements
are incorrect.
Model E310
LVPS to Interconnect Board
Cable
Check the continuity of the LVPS to
interconnect board cable. Replace
the cable if it does not measure
continuity.
Model E310
Interconnect Board
Reconnect the LVPS to the
interconnect board cable. Go to
“Interconnect Board (model E310)”
on page 5-21
and measure voltages
on the following connectors on the
interconnect board:
CN401/CN402/CN403/CN404/
CN405/CN407/CN408
If any of the measured voltages are
incorrect, replace the interconnect
board.
Model E312
Power Switch
Place the printer on its rear side.
Position the LVPS board on a flat
surface with all the cables
connected. Turn the printer power
switch to the on position. Check the
AC line voltage at power switch
connector CN501. If no voltage is
present, replace the power switch
FRU
Action
Summary of Contents for Optra 4044-XXX
Page 6: ...vi 4044 XXX Laser Advisory Label ...
Page 7: ...vii 4044 XXX Class 1 Laser Statement Label ...
Page 14: ...xiv 4044 XXX Japanese Laser Notice Chinese Laser Notice ...
Page 19: ...xix 4044 XXX Chinese Safety Information Korean Safety Information ...
Page 20: ...xx 4044 XXX ...
Page 58: ...2 36 Service Manual 4044 XXX ...
Page 73: ...Diagnostic Aids 3 15 4044 XXX Paper Path ...
Page 74: ...3 16 Service Manual 4044 XXX ...
Page 77: ...Repair Information 4 3 4044 XXX 2 Remove the face up cover 3 Open the front cover ...
Page 84: ...4 10 Service Manual 4044 XXX HVPS 1 Remove all covers 2 Remove the HVPS board mounting screws ...
Page 96: ...4 22 Service Manual 4044 XXX ...
Page 99: ...Connector Locations 5 3 4044 XXX ...
Page 104: ...5 8 Service Manual 4044 XXX ...
Page 109: ...Connector Locations 5 13 4044 XXX ...
Page 111: ...Connector Locations 5 15 4044 XXX ...
Page 116: ...5 20 Service Manual 4044 XXX ...
Page 119: ...Connector Locations 5 23 4044 XXX ...
Page 120: ...5 24 Service Manual 4044 XXX ...
Page 122: ...6 2 Service Manual 4044 XXX Assembly 1 Covers ...
Page 124: ...6 4 Service Manual 4044 XXX Assembly 1 Covers continued ...
Page 126: ...6 6 Service Manual 4044 XXX Assembly 2 Frame ...
Page 128: ...6 8 Service Manual 4044 XXX Assembly 2 Frame continued ...
Page 130: ...6 10 Service Manual 4044 XXX Assembly 3 Fuser ...
Page 132: ...6 12 Service Manual 4044 XXX Assembly 3 Fuser continued ...
Page 134: ...6 14 Service Manual 4044 XXX Assembly 4 Main Drive ...
Page 136: ...6 16 Service Manual 4044 XXX Assembly 5 Paper Feed ...
Page 138: ...6 18 Service Manual 4044 XXX Assembly 5 Paper Feed continued ...
Page 140: ...6 20 Service Manual 4044 XXX Assembly 6 Electronics model E310 ...
Page 142: ...6 22 Service Manual 4044 XXX Assembly 6 Electronics model E310 continued ...
Page 144: ...6 24 Service Manual 4044 XXX Assembly 6 Electronics model E312 ...
Page 148: ...6 28 Service Manual 4044 XXX ...