User Manual
Publication date: May, 2005
Revision A1
209
alarm
<<events>>
set
Syntax
:
set sms <range>
set email <range>
set trap <range>
set all <range>
Description
:
The Set here is used for the activation of sms, email and trap event.
Argument
:
<range>: syntax 1,5-7, trap number.
Possible value:
available from 1 to 24
Example:
GSW-1291(alarm-events)# set sms 1-3
GSW-1291(alarm-events)# set email 1-3
GSW-1291(alarm-events)# set trap 1-3
GSW-1291(alarm-events)# set all 1-3
del
Syntax
:
del sms <range>
del email <range>
del trap <range>
del all <range>
Description
:
The Del here is used for the de-activation of sms, email and trap event.
Argument
:
<range>:trap number.
Possible value:
available from 1 to 24
Example:
GSW-1291(alarm-events)# del sms 1-3
GSW-1291(alarm-events)# del email 1-3
GSW-1291(alarm-events)# del trap 1-3
GSW-1291(alarm-events)# del all 1-3