stp
enable
Syntax
:
enable
Description
:
To enable the STP function.
Argument
:
None
Possible value:
None
Example:
GSW-1291(stp)# enable
disable
Syntax
:
disable
Description
:
To disable the STP function.
Argument
:
None
Possible value:
None
Example:
GSW-1291(stp)# disable
set config
Syntax
:
set config <Bridge Priority> <Hello Time> <Max. Age> <Forward Delay>
Description
:
To set up the parameters of STP.
Argument
:
<Bridge Priority> :Priority must be a multiple of 4096,available from 0 to 61440.
<Hello Time>: available from 1 to 10.
<Max. Age>: available from 6 to 40.
<Forward Delay>: available from 4 to 30.
Possible value:
<Bridge Priority> 0 to 61440.
<Hello Time>: 1 to 10.
<Max. Age>: 6 to 40.
<Forward Delay>: 4 to 30.
Example:
GSW-1291(stp)# set config 61440 2 20 15