gvrp
enable
Syntax
:
enable
Description
:
To enable the gvrp function.
Argument
:
None
Possible value:
None
Example:
GSW-1291(gvrp)# enable
disable
Syntax
:
disable
Description
:
To disable the gvrp function.
Argument
:
None
Possible value:
None
Example:
GSW-1291(gvrp)# disable
set timer
Syntax
:
set timer <range> <join> <leave> <leaveall>
Description
:
To set gvrp join time, leave time, and leaveall time for each port.
Argument
:
<range> : port range
<join>: join timer
<leave>: leave timer
<leaveall>: leaveall timer
Possible value:
<range> : syntax 1,5-7, available from 1 to 12
<join>: available from 20 to 100
<leave>: available from 60 to 300
<leaveall>: available from 1000 to 5000
Leave Time must equal double Join Time at least.
Example:
GSW-1291(gvrp)# set timer 2-8 25 80 2000