6.3.3 Cable lengths
The following maximum line lengths to be used must be observed:
Table 6.2:
Cable lengths
6.4
Disassembling, packing, disposing
Repacking
For later re-use, the device is to be packed so that it is protected against shocks and humidity. Optimum
protection is achieved when using the original packaging.
Connection
Interface
Max. cable length
Shielding
BCL 8 direct
RS 232
< 3m
Required
BCL 8 – MA 8.1
RS 232
< 3m
Required
BCL 8 – MA 8-01
RS 232
< 3m
Required
MA 8.1 – host
RS 232
< 10m
Required
MA 8-01 – host
RS 485
< 25m
Required
Switching input/output
< 10m
Not necessary
NOTE
The RS 232 connection between BCL 8 and host must not exceed a total of 10m.
NOTE
Electrical scrap is a special waste product!
Observe the locally applicable regulations regarding disposal of the product.