Configuration and diagnostics software - Sensor Studio

Leuze electronic GmbH + Co. KG

BCL 8

35

9

Configuration and diagnostics software - Sensor Studio

The 

Sensor Studio

 configuration software provides a graphical user interface for operation, configuration 

and diagnosis of the device via the RS 232 service interface.
A device that is not connected to the PC can be configured offline.
Configurations can be saved and reopened as projects for transferring back to the device at a later time.

The 

Sensor Studio

 configuration software is designed according to the FDT/DTM concept:

• You make the individual configuration settings for the bar code reader in the Device Type Manager 

(DTM).

• The individual DTM configurations of a project can be called up via the frame application of the Field 

Device Tool (FDT).

• Communication DTM for bar code readers: 

LeCommInterface

• Device DTM for BCL 8 bar code reader

Procedure for the installation of the software and hardware:

Install the 

Sensor Studio

 configuration software on the PC. Install the communication and device DTM. 

Communication and device DTMs are included in the 

LeAnalysisCollectionSetup

 installation package.

Create the device DTM for BCL 8 in the project tree of the 

Sensor Studio

 FDT frame.

Connect the bar code reader to the PC (see chapter  "Connecting").

Activate service interface on bar code reader (see chapter  "Activate service interface").

9.1

System requirements

To use the 

Sensor Studio

 configuration software, you need a PC or laptop with the following specifications:

Table 9.1:

System requirements for 

Sensor Studio

 installation

NOTE

Only use the 

Sensor Studio

 configuration software for products manufactured by Leuze.

The 

Sensor Studio

 configuration software is offered in the following languages: German, 

English, French, Italian and Spanish.
The FDT frame application of 

Sensor Studio

 supports all languages; it is possible that not all 

languages are supported in the device DTM (Device Type Manager).

Operating system 

Windows XP or higher (32 bit, 64 bit)

Windows Vista

Windows 7

Windows 8

Computer 

Processor type: 1 GHz or higher

Serial COM interface

CD-ROM drive

Main memory (RAM): at least 64 MB

Keyboard and mouse or touchpad

Graphics card 

At least 1024 x 768 pixels

Required hard disk capacity for 

Sen

-

sor Studio 

and communication DTM

35 MB

NOTE

Administrator privileges on the PC are necessary for installing 

Sensor Studio

.

Summary of Contents for BCL 8

Page 1: ...BCL 8 Bar code reader with integrated decoder Original operating instructions EN 2022 04 14 50127073 We reserve the right to make technical changes...

Page 2: ...Leuze electronic GmbH Co KG BCL 8 2 2022 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de...

Page 3: ...5 2 2 MA 8 1 PWR IN HOST RS232 voltage supply and RS 232 20 5 2 3 MA 8 1 SW IN OUT switching input and switching output 21 5 2 4 MA 8 1 BCL connecting the BCL 8 to the MA 8 1 22 5 3 Connection unit M...

Page 4: ...6 Switching input tab 46 9 5 7 Switch tab 47 9 6 Diagnosis 48 9 7 Firmware Reload 48 10 Starting up the device Configuration 50 10 1 Measures to be performed prior to the initial commissioning 50 10 2...

Page 5: ...sal rod mounting system for BCL 8 26 Figure 6 1 BCL 8 device name plate 27 Figure 6 2 Definition of the BCL 8 reading angles 28 Figure 6 3 BCL 8 pin assignment 29 Table 6 1 Wiring description BCL 8 29...

Page 6: ...cable European standards and directives The manufacturer of the product Leuze electronic GmbH Co KG in D 73277 Owen possesses a certi fied quality assurance system in accordance with ISO 9001 ATTENTIO...

Page 7: ...tic analyzers For space critical bar code reading tasks Material flow Pharmaceutical industry Robotics and automation technology CAUTION Observe intended use Only operate the device in accordance with...

Page 8: ...s DGUV V3 e g electrician foreman In other countries there are respective regulations that must be observed 2 4 Exemption of liability Leuze electronic GmbH Co KG is not liable in the following cases...

Page 9: ...Safety Leuze electronic GmbH Co KG BCL 8 9 Figure 2 1 Laser apertures laser warning signs A Laser aperture B Laser warning sign A B A B BCL 8 S 2 BCL 8 S 0...

Page 10: ...ion unit The MA 8 1 connection unit simplifies the electrical installation of the bar code reader in stand alone oper ation with an RS 232 interface For details on the connection units see Chapter 5 W...

Page 11: ...so that the voltage supply of the BCL 8 MA 8 1 is ensured TxD to RxD of the RS 232 is established from one BCL 8 to the next host the switching outputs and inputs are connected optional A maximum of s...

Page 12: ...ng output etc Electrical data Interface type RS 232 freely configurable Baud rate 4800 57600 Bd Data formats Data bits 7 8 Parity none even odd Stop bit 1 2 Protocols Framing protocol with without ack...

Page 13: ...xclusively in Class 2 circuits according to NEC 2 These bar code readers shall be used with UL Listed Cable assemblies rated 30V 0 5A min in the field installation or equivalent categories CYJV CYJV7...

Page 14: ...0 BCL 8 S N 0 with lateral beam exit Figure 4 1 Dimensioned drawing BCL 8 S M 0 BCL 8 S N 0 with lateral beam exit A Turning connector turnable 90 B Indicator LEDs B1 status LED B2 decode LED C Scanni...

Page 15: ...front beam exit Figure 4 2 Dimensioned drawing BCL 8 S M 2 BCL 8 S N 2 with front beam exit A Turning connector turnable 90 B Indicator diodes B1 status LED B2 decode LED C Scanning beam divergence ma...

Page 16: ...n mm Connection Scanner type Beam exit Part no BCL 8 S M 100 Up to 160mm 0 15 0 5 M12 connector Single line Lateral 50040229 BCL 8 S M 102 Single line Front 50038949 BCL 8 S M 550 Fixed cable 2m Singl...

Page 17: ...0 150 mm 6 mil m 0 2 mm 8 mil m 0 3 mm 12 mil m 0 5 mm 20 mil BCL 8 S M 100 BCL 8 S M 550 BCL 8 S M 102 BCL 8 S M 552 Reading field width in mm Distance in mm Code 2 5 int Ratio 1 2 5 Class A acc to...

Page 18: ...sor mounting bracket for rod 12 mm or cheek 1 5 4 mm BTU 300M D14 50117251 Sensor mounting bracket for rod 14 mm or cheek 1 5 4 mm BTU D12M 5 150 50119323 Rod 12 mm length 150 mm stainless steel BTU D...

Page 19: ...The connection unit offers the following advantages over the installation of the BCL 8 as a stand alone device M12 socket for switching input and switching output M12 connector for RS 232 interface a...

Page 20: ...2 connector A coded S S PWR IN HOST RS232 5 pin connector A coded Pin Name Comment 1 VIN Positive supply voltage 10 30VDC 2 TXD RS 232 transmit data from the BCL 8 to the host 3 GND Supply voltage 0VD...

Page 21: ...SWIN Switching input 5 FE Functional earth Thread FE Functional earth housing ATTENTION Degree of protection IP 67 is achieved only if the connectors and caps are screwed into place NOTE The switchin...

Page 22: ...N Supply voltage for BCL 8 4 9 5 4VDC 2 TXD RS 232 transmission line 3 GND Supply voltage 0VDC 4 RXD RS 232 receiving line 5 SWIN SWOUT Programmable switching input output of the BCL 8 Thread FE Funct...

Page 23: ...IP 67 is achieved only if the connectors and caps are screwed into place Electrical data Interface type RS 485 Service interface No MA 8 01 connected RS 232 with default data format 9600Bd 8 data bits...

Page 24: ...in Name Comment 1 VOUT Voltage supply for sensor system VOUT identical to VIN at PWR IN 2 SWOUT Switching output 3 GND GND for the sensor system 4 SWIN Switching input 5 FE Functional earth Thread FE...

Page 25: ...in socket A coded Pin Name Comment 1 VIN Supply voltage for BCL 8 approx 5 2VDC 2 TXD RS 232 transmission line 3 GND Supply voltage 0VDC 4 RXD RS 232 receiving line 5 SWIN SWOUT Programmable switching...

Page 26: ...of mounting devices are available for mounting the BCL 8 These are designed for rod or screw mounting see also the Leuze Catalog Series 8 Accessories Universal rod mounting system Figure 5 13 Universa...

Page 27: ...estions concerning your shipment please contact your supplier or your local Leuze sales office Observe the applicable local regulations when disposing of the packaging materials Cleaning Clean the gla...

Page 28: ...ct to the interface Figure 6 2 Definition of the BCL 8 reading angles Mounting location When choosing the mounting location observe the following maintaining the required environmental conditions temp...

Page 29: ...ion IP 67 and the warranty Before connecting the device be sure that the supply voltage agrees with the value printed on the name plate Connection of the device and maintenance work while under voltag...

Page 30: ...ic setting the SW IN OUT switching output is switched to GND pin 3 if a code is recognized Figure 6 6 Switching output BCL 8 ATTENTION Do not load the respective switching output of the BCL 8 with mor...

Page 31: ...ection is achieved when using the original packaging Connection Interface Max cable length Shielding BCL 8 direct RS 232 3m Required BCL 8 MA 8 1 RS 232 3m Required BCL 8 MA 8 01 RS 232 3m Required MA...

Page 32: ...regarding the various setting options refer to Chapter 9 or the online help of the Sensor Studio program To operate the BCL 8 it is normally sufficient to set code type and code length in accordance w...

Page 33: ...ated by holding a defined bar code label Service see Figure 7 1 in front of the reading window during power up initialization phase Figure 7 1 Bar code label Service While the laser switches on for ap...

Page 34: ...wing a serious error you should reinitialize the BCL 8 It will then usually again function properly If a hardware problem is present the BCL 8 will not reinitialize Warnings and errors which occur fre...

Page 35: ...re included in the LeAnalysisCollectionSetup installation package Create the device DTM for BCL 8 in the project tree of the Sensor Studio FDT frame Connect the bar code reader to the PC see chapter C...

Page 36: ...C voltage supply is to be fed in externally see chapter 6 3 Connecting 9 3 Starting Sensor Studio Prerequisites 3 The device has been mounted see chapter 6 2 Mounting and connected see chapter 6 3 Con...

Page 37: ...ar code reader D In the Sensor Studio FDT frame click the Establish connection with device button D In the Sensor Studio FDT frame click the Upload parameters to device button D The current configurat...

Page 38: ...rding the configuration parameters of the device manager DTM for the bar code reader The Sensor Studio configuration software offers the following buttons in the CONFIGURATION menu Reset all parameter...

Page 39: ...under Interval mode Up to three fixed element numbers with comma e g 8 13 elements Both are also possible but the range must be specified first select Interval mode e g 4 10 20 elements Labels to be d...

Page 40: ...e to the left and right By default the scanner checks a quiet zone that is 7x greater than the module Reading reliability Reading reliability equal scans Under Reading security equal scans it is possi...

Page 41: ...message before the read result Label header The label header is set directly before the code data Label footer The label footer is appended directly to the code data Message mode Selects whether the...

Page 42: ...erent to the previous read result When rack reading for example this is used to set that the codes within adjacent samples are only output once Deletion of code output memory Difference memory timeout...

Page 43: ...combination with Autostart after decoding Is normally used for test purposes Switching input 1 Function See menu switching input Immediately after the complete decoding result is available If the set...

Page 44: ...de reader standard procedure The desired acknowledgment settings are also to be set in this selection window Properties dialog box Framing Protocol Figure 9 10 Standard settings of the Properties dial...

Page 45: ...se the switching output must be set to Reference Code Compare Positive Reference Code Compare or Negative Reference Code Compare in the switching output switch menu One possibility to save the referen...

Page 46: ...Switching input tab Figure 9 13 Switching input tab NOTE The configuration options are identical for both switching inputs SWIN 1 and SWIN 2 Inverted Here the input level can be inverted Debounce tim...

Page 47: ...ctivated the pulse duration parameter should be 0 NOTE Type and source of the danger The configuration options are identical for both switching outputs SWOUT 1 and SWOUT 2 Activation Select the desire...

Page 48: ...commands command V You can use this command to check whether the communication between PC and scanner is functional If you do not receive an acknowledgment please check the interface connections or th...

Page 49: ...e Reload tool click on the Start Reload button to load the new firmware into the device The device is connected via the serial interface specified under Port The Firmware Reload tool checks whether th...

Page 50: ...ceed in the event of problems during commissioning of the devices see chapter 12 3 Diagnostics and troubleshooting If a problem occurs that cannot be rectified even after checking all electrical conne...

Page 51: ...r sets are explained to understand what is happening during configuration parameter setting see chapter 7 3 1 Parameter sets The setting of code type and code length is usually accomplished by using t...

Page 52: ...ommissioned after delivery With the Sensor Studio configuration software via the Factory Default button in the DIAGNOSIS menu After the online command PC20 see chapter 11 1 3 Online commands for param...

Page 53: ...he command parameter s Both small and capitalized letters can be used Example Command CA autoConfig function Parameter Activation Transmitted is CA Notation Commands command parameters and returned da...

Page 54: ...the BCL 8 reads while the autoConfig function is active Parameter Activates autoConfig Rejects the last code read Deactivates autoConfig and stores the decoded data in the current parameter set Ackno...

Page 55: ...code 3 Reference code has not been saved 4 Reference code invalid Example Entry RS130678654331 Code 1 1 RAM only 3 UPC 06 code information Command RT Description This command enables a reference code...

Page 56: ...lignment of the BCL 8 in static installation situations After activating the function with JP the scan ner continuously supplies status information to the serial interfaces With this online command th...

Page 57: ...ameter None Acknowledgment None Command Description The command activates decoding Parameter None Acknowledgment None Command OA Description The command activates a selected switching output Parameter...

Page 58: ...ge The sequence of the data is arranged identically to the BCL 8 i e when a word is transmitted first the low byte is sent then the high byte The parameter set data is converted for transmission from...

Page 59: ...lock check checksum 5 invalid data length 6 invalid message data 7 invalid start address 8 invalid parameter set 9 invalid parameter set type Example PC20 loads the default parameters Command PR Descr...

Page 60: ...e defined address and stores them in an intermediate buffer If the status indicates that further messages follow these are also stored in the intermediate buffer before they are then stored under the...

Page 61: ...ply voltage Status LED flashing red There is a device warning Query diagnostic data in the device and carry out the resulting measures or reset Status LED continuous red light Serious error no functio...

Page 62: ...ther with a description Please register the merchandise concerned Simply register return of the merchandise on our website www leuze com under Contact Support Repair Service Returns To ensure quick an...

Page 63: ...Figure 12 1 Example bar code label types Code type 01 Interleaved 2 of 5 Module 0 3 Code type 02 Code 39 Module 0 3 Code type 11 Codabar Module 0 3 Code 128 Module 0 3 Code type 08 EAN 128 Module 0 3...

Reviews: