Technical data
Leuze electronic GmbH + Co. KG
BCL 8
16
4.4
Optical data
For different reading task and connection requirements, the BCL 8 is available in various models (see
chapter 4.4.1 "Type overview").
4.4.1 Type overview
BCL 8 with M optics
Table 4.3:
Type overview - M optics
BCL 8 with N optics
Table 4.4:
Type overview - N optics
4.4.2 Reading fields
NOTE
Please note that the size of the bar code module influences the maximum reading distance and
the width of the reading field. Therefore, when selecting a mounting location and/or the bar code
label, take into account the different reading characteristics of the scanner with various bar code
modules.
Type
Operating
range
Module/
resolution
[mm]
Connection
Scanner type/
Beam exit
Part no.
BCL 8 S M 100
Up to 160mm
0.15 … 0.5
M12
connector
Single line/
Lateral
50040229
BCL 8 S M 102
Single line/
Front
50038949
BCL 8 S M 550
Fixed cable
(2m)
Single line/
Lateral
50040230
BCL 8 S M 552
Single line/
Front
50038948
Type
Operating
range
Module/
resolution
[mm]
Connection
Scanner type/
Beam exit
Part no.
BCL 8 S N 100
Up to 120mm
0.125 … 0.4
M12
connector
Single line/
Lateral
50105417
BCL 8 S N 102
Single line/
Front
50105418
BCL 8 S N 550
Fixed cable
(2m)
Single line/
Lateral
50105419
BCL 8 S N 552
Single line/
Front
50105420
NOTE
Please note that the actual reading fields are also influenced by factors such as labeling material,
printing quality, reading angle, printing contrast etc., and may thus deviate from the reading fields
specified here. The origin of the read distance always refers to the front edge of the housing of
the beam exit.