9.5.2 Output tab
Figure 9.6:
Output
tab (OUTPUT FORMAT)
Properties dialog box (Common Properties)
Set the desired formatting modes and formatting characters as necessary.
Output header
Select from the options listed below. The output header is sent in
a separate message before the read result.
Label header
The label header is set directly before the code data.
Label footer
The label footer is appended directly to the code data.
Message mode
Selects whether the bar codes read are sent in concatenation or
separately as individual strings.
NOTE
The structure of this message string is depicted symbolically in the preview window.
Text in the case of misreading
(No read string)
This character is set for each unrecognized bar code. Multiple
characters (=string) may be entered here. Up to 20 characters are
possible.