Configuration and diagnostics software - Sensor Studio
Leuze electronic GmbH + Co. KG
BCL 8
39
Figure 9.4: Standard settings of the Properties dialog box (SYMBOLOGY PROPERTIES)
Code table
(CODE TABLE)
Here, the codes which are to be decoded are set.
Codes which are not enabled are not decoded!
Note:
We recommend enabling only the code types which are to actu
-
ally be read with the corresponding element number.
Element number
In the field Element number, up to three element entries may be
entered.
A range of permissible elements is indicated by a dash:
e.g., 4-40 elements.
To select a range, set the check mark under Interval mode. Up to
three fixed element numbers with comma:
e.g.: 8,13 elements
Both are also possible, but the range must be specified first
(select Interval mode):
e.g.: 4-10,20 elements
Labels to be decoded
(COMPLETENESS / Number of bar
codes)
Here, the number of the bar codes to be decoded within a read
cycle (one reading gate) is set.
NOTE
If the code EAN128 is to be read, 3 additional characters must be set here for the code identifier.
Properties
(Symbology Properties)
In the Symbology Properties window to the right of the respective
code, the code-specific settings such as the check digit can be
selected after Element number.
Alternatively, you can select the property settings directly via the
navigation tree with the [Symbologies] button.
The properties can be individually set for each code type.