Commissioning
Leuze electronic
BCL 40
51
TNT
35/7-2
4
V
7
Commissioning
7.1
Measures to be performed prior to the first commissioning
©
Before commissioning, familiarise yourself with the operation and configuration of the
device(s)!
©
Before switching on, recheck all connections and ensure that they have been properly
made.
Figure 7.1:
Control elements of the MA 10
Reset button:
- Press < 4s:
"warm start"
- Press > 4s:
"cold start"
DIP-switch 1 "ParaDefault":
ON
on reset (’cold start’) fac-
tory setting parameter set
is loaded
OFF on reset (’cold start’) cus-
tomer-specific parameter
set is loaded
DIP switch 2 "autoConfig"
and parallel connected jump-
er:
ON "autoConfig"
function
activated
OFF "autoConfig"
function
deactivated
Data logging jumper for
the interface terminal
- Jumper above: Data from Host
- Jumper below*: Data from BCL
Jumper for setting the
device address range:
- Right jumper Addr. 0 … 15
- Left jumper
Addr. 16 … 31
Coding switch 0 … F for setting
the device address:
The switch positions 0 … F
correspond to the device ad-
dress 0 … 15 or 16 … 31.
Interface terminal
RS 232 for commis-
sioning and service
Operating modes switch:
Switch setting 1:SERVICE*
Switch setting 2:OPERATION
*In service operation, the jumper must be in the "lower"
position. Communication is otherwise not possible.