![Leuze BCL 40 Technical Description Download Page 15](http://html1.mh-extra.com/html/leuze/bcl-40/bcl-40_technical-description_1883763015.webp)
Leuze
electronic
Description
Leuze electronic
BCL 40
13
TNT
35/7-2
4
V
Figure 3.2:
Networking possibilities using the multiNet plus
Two-wire RS 485
The Leuze MultiNet plus is optimised for fast transmission of scanner data to a primary host
computer. The multiNet plus physically consists of a two-wire RS 485 interface through
which the multiNet plus software protocol is controlled. Thus network connection is very
simple and inexpensive: the network connection is simply passed through to the next slave.
Interface modules
Shielded, twisted pair conductors should be used for the multiNet. This allows a total
network length of up to 1200m.
Connection of the network to the primary computer is made via the host interface of the MA
30 which can be equipped with 4 different physical interface modules. Modules for RS 232,
RS 422, TTY and RS 485 are available.
Slave
MA 10
Slave
MA 10
Slave
MA 10
RS 232
RS 422
RS 485 or
TTY
-Backup
parameters
Voltage
supply
Network master
multiNet plus
MA 30
RS 485
Sensor
Sensor
Sensor
Sensor
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]