Mounting BCL 40 and MA 10
You can fasten the scanner BCL 40 and connector unit MA 10 tightly together to form a
single compact unit.
©
Plug the two devices together at the 15 pin Sub D connector.
Be sure that there is no dirt in the area of the seal (this guarantees an IP 65 protection
class). Insert the two M4 x 30 screws included with the connector unit MA 10 into the
countersunk drill holes on the bottom side of the MA 10, screw them into the correspond-
ing threads in the BCL 40 and tighten them down.
There are three basic mounting arrangements for the BCL 40 / MA 10 unit:
• using the dovetail groove of the BCL 40 or the MA 10 and the corresponding mount-
ing accessories
• using the two upper fastening threads on the rear of the BCL 40
• using the four fastening threads on the underside of the MA 10 (see chapter 4.4
"Dimensioned drawings")
Notice!
The cable screw glands of the MA 10 can be set either on the right or the left side of the unit.
Loosen the four Phillips screws on the back side of the MA 10, carefully lift off the cover, re-
place it into the desired position and tighten down the four screws again. Be careful not to
damage the ribbon cable.
Figure 6.3:
Mounting example for the combined BCL 40 / MA 10 unit