Installation
Leuze
electronic
44
BCL 40
Leuze electronic
RS 485 interface
Figure 6.13: Connecting the MA 10 to a RS 485 Host
RS 232 interface
Figure 6.14: Connecting the MA 10 to a RS 232 Host
Notice for connecting the RS 232 interface:
The wiring for RTS and CTS must only be connected, if RTS/CTS hardware-handshake is
used.
R
S4
8
5
485A 1
485A 2
485B 3
485B 4
G N D 5
G N D 6
12
3
4
5
6
4 8 5 A
485B
G N D
485A
4 8 5 B
G N D
Host
Shield
Host interface module
up to 1200m
Shield
12
3
4
5
6
RS232
R X D 1
T
X D 2
C TS 3
R TS 4
- 5
G N D 6
RXD
TXD
C
T
S
RT S
GND
Host
Shield
Host interface module
up to 10m