Electrical connection
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
71
Figure 7.8: BCL 301
i
- MK 301 terminal hood with spring-loaded terminals
Cable fabrication and shielding connection
Remove approx. 78 mm of the connection cable sheathing. 15 mm of sheath of the shielded line must be
freely accessible.
Figure 7.9: Cable fabrication for MK 301 terminal hood
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when
the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end
sleeves are not necessary.
NOTE
The integrated parameter memory for the simple replacement of the BCL 301
i
is located in the
MK 301.
NOTE
The bus is looped through the MK 301, i.e. the bus is not interrupted when the BCL 301
i
is
removed from the MK 301. The bus is terminated via slide switch T in the MK 301. If the termi
-
nation is activated (slide switch T in the ON position), the downstream bus is disconnected.
NOTE
Dimensioned drawing on see chapter 5.3.6 "Dimensioned drawings of MS 3xx / MK 3xx connec
Terminal hood
MK 301
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
Mini-B USB socket
(behind protective cap)
Te
rmin
al blo
ck
PW
R
/ SW
IN
/O
UT
Te
rmin
al blo
ck
HOST
/ BUS I
N
Te
rmin
al blo
ck
BUS OUT
Slide switch T: bus
termination
Slide switch S1:
multiNet address range
low (0 … 15) / high
(16 … 31)
Rotary switch S2:
multiNet address
0 … 15
ON
OF
F
Terminal designation
MK 301
≈ 55 mm
≈ 8 mm
≈ 15 mm