Electrical connection
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
66
7.2
BCL 300
i
electrical connection
For the electrical connection of the BCL 300
i
, 4 connection variants are available.
The voltage supply (18 … 30VDC) is connected acc. to the connection type selected.
2 freely programmable switching inputs/outputs for individual adaptation to the respective application are
also available here. Detailed information on this topic can be found in Chapter 7.4.1 and Chapter 7.4.3.
7.2.1 MS 300 connector hood with 2 integrated M12 connectors
The MS 300 hood with integrated connectors features two M12 connector plugs and a Mini-B type USB
socket as a service interface. Parameter memory is integrated into the MS 300 which temporarily stores
the settings of the BCL 300
i
in the case of replacement and transmits them to a new device.
Figure 7.2: BCL 300
i
- MS 300 hood with integrated M12 connectors
NOTE
The shielding connection is done via the M12 connector housing.
NOTE
The integrated parameter memory for the simple replacement of the BCL 300
i
is located in the
MS 300.
NOTE
Dimensioned drawing on see chapter 5.3.6 "Dimensioned drawings of MS 3xx / MK 3xx connec
HOST / BUS IN
GND_ISO 3
2
1
4
RXD/RX-
TXD/TX-
RTS/TX+
CTS/RX+
5
PWR / SW IN/OUT
SWIO_2
SWIO_1
3
2
1
4
5
GNDIN
VIN
FE
SERVICE
2
1 3 5
4
GND
D+
D-
VB
ID
BUS OUT
Mini-B USB socket
(behind protective cap)
M12 connector
(A-coded)
M12 connector
(B-coded)
Dummy plug
Connector hood
MS 300