Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
21
MultiNet operation BCL 301
i
If the BCL 301
i
detects an address larger than 0 after connecting the supply voltage, it registers itself with
the multiNet master via the multiNet. If the device is detected in the network, the NET LED turns green and
the BCL 301
i
is ready.
By connecting voltage (18 … 30VDC) on the switching input, a read process is activated. In the standard
setting, all common code types for decoding are released; only the 2/5 Interleaved code type is limited to
10 digits of code content.
If a code is lead through the reading field, the code content is decoded and passed to the master via the
multiNet.
NOTE
The configuration of the device can be changed or the functions can be tested via the USB
service interface. To do this, connecting the supply voltage to the device and establishing a USB
connection between the BCL and PC is sufficient.
At www.leuze.com, you can find a USB driver for webConfig under Download -> identify ->
Stationary bar code readersBCL 300
i
\ BCL 301
i
. Install this USB driver and please follow the
instructions when doing so. Then, you can open the connection to the BCL through your Internet
browser and perform the desired settings or tests.