Technical data
Leuze electronic GmbH + Co. KG
BCL 300
i
\ BCL 301
i
37
5.2.3 Line scanner / raster scanner with deflecting mirror and heating
Technical data same as for line scanner without heating, however with the following differences:
Electrical data
Operating voltage
24VDC ±20%
Power consumption
Max. 26W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor cross
section
Conductor cross section of at least 0.75mm² for the supply voltage supply line.
Wiring through of the voltage supply to multiple heating devices is not permissible.
Standard, M12 ready-made cable not usable
(insufficient cable cross-section)
Environmental data
Operating temperature
range
-35°C … +40°C
Storage temperature
range
-20°C … +70°C
Type
BCL 300
i
Stand-alone
BCL 301
i
multiNet plus slave
Design
Oscillating-mirror scanner with heating
Table 5.5:
Specifications of the BCL 301
i
and BCL 300
i
oscillating-mirror scanners with heating
Type
BCL 300
i
Stand-alone
BCL 301
i
multiNet plus slave
Design
Deflecting mirror scanner with heating
Optical data
Useful opening angle
Max. 60°
Electrical data
Operating voltage
24VDC ±20%
Power consumption
Max. 19W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30 min at +24 V DC and an ambient temperature of -35 °C
Min. conductor cross
section
Conductor cross section of at least 0.75mm² for the supply voltage supply line.
Wiring through of the voltage supply to multiple heating devices is not permissible.
Standard, M12 ready-made cable not usable
(insufficient cable cross-section)
Environmental data
Operating temperature
range
-35°C … +40°C
Storage temperature
range
-20°C … +70°C
Table 5.6:
Specifications of the BCL 301
i
and BCL 300
i
deflection-mirror scanners with heating