Device description
Leuze electronic GmbH + Co. KG
BCL 208i
17
PWR LED
Tab. 4.1:
PWR indicators
Color
State
Description
---
OFF
Device off
No supply voltage
Green
Flashing
Device ok
• Initialization phase
• Bar code reading not possible
• Supply voltage applied
• Self test running
Continuous light
Device ok
• Bar code reading possible
• Self test successfully finished
• Device monitoring active
Briefly off - on
Good Read
• Bar code reading successful
Green briefly off –
briefly red – green on
No read
• Bar code reading not successful
Orange
Continuous light
Service mode
• Bar code reading possible
• No data on the host interface
Red
Flashing
Device ok, warning set
• Bar code reading possible
• Temporary operating fault
Continuous light
Device error/parameter enable
• Bar code reading not possible
NET LED
Tab. 4.2:
NET indicators
Color
State
Description
---
OFF
No supply voltage
• No communication possible
• Ethernet protocols not released
Green
Flashing
Initialization of the device
Establishing communication
Continuous light
Operation ok
• Network mode ok
• Connection and communication to Host established
Red
Flashing
Communication error
• Temporary connection error
• If DHCP is active, no address could be obtained
Continuous light
Network error
• No connection established
• No communication possible