Fast commissioning
Leuze electronic GmbH + Co. KG
BCL 208i
12
3.5
Further settings
Carry out further settings, such as the control of the decoding and processing of the read data and the con-
figuration of the connected switching inputs and outputs.
Decoding and processing the read data
Ä
Define at least one code type with the desired settings.
In the webConfig tool:
Configuration > Decoder
Control of the decoding
Configure the connected switching input according to your requirements.
Ä
Configure the switching behavior.
In the webConfig tool:
Configuration > Device > Switching inputs/outputs
Control of the switching output
Configure the connected switching output according to your requirements.
Ä
Configure the switching behavior.
In the webConfig tool:
Configuration > Device > Switching inputs/outputs
3.6
Starting the device
Ä
Connect the +18 … 30 V DC supply voltage (typ24 V DC).
ð
The BCL 208i starts up, the PWR, NET and LINK LEDs indicate the operating state.
Tab. 3.1:
Display of operating state
LED
Color
State
Description
PWR
Green
Flashing
Device ok, initialization
Continuous light
Power On, device OK
Briefly off - on
Good read, reading successful
Green - red
Green off – briefly
red – green on
No Read, reading not successful
Yellow
Continuous light
Service mode
Red
Flashing
Warning
Continuous light
Error, device error
NET
Green
Flashing
Initialization
Continuous light
Network mode ok
Red
Flashing
Communication error
Continuous light
Network error
LINK
Green
Continuous light
Ethernet connected (LINK)
Yellow
Flashing
Data communication (ACT)
During the initialization phase (power on), the laser is switched on for approx. 2 seconds. A configuration
code can be read in during this time.