Fast commissioning
Leuze electronic GmbH + Co. KG
BCL 208i
10
1
2
2
3
1
4
5
1
3
2
4
1 PWR/SWIO
2 HOST
1
PWR/SWIO, M12 connector, 5-pin, A-coded
2
HOST, M12 socket, 4-pin, D-coded
Fig. 3.1:
Electrical connections
NOTICE
The shielding is connected using the M12 connector of the Ethernet cable.
Details on the connectors see chapter 6 "Electrical connection".
3.4
Preparatory settings
Ä
Connect the +18 … 30 V DC supply voltage (typ24 V DC).
ð
The bar code reader starts up.
First, you must now set the communication parameters of the BCL 208i. Make the necessary settings via
the webConfig tool, see chapter 8 "Starting up the device - Configuration".
3.4.1
Manually setting the IP address
Set the IP manually if your system does not include a DHCP server or if the IP addresses of the devices
are to be set permanently.
Ä
Have the network administrator specify the data for IP address, net mask and gateway address of the
BCL 208i.
Ä
Set the values on the BCL 208i.
In the webConfig tool:
Configuration > Communication > Ethernet interface
NOTICE
Ä
After making the setting via the webConfig tool, restart the BCL 208i.
ð
The set IP address is only accepted and active after a restart.