Online commands
Leuze electronic GmbH + Co. KG
BCL 208i
42
Software reset
Command
’H’
Description
Carries out a software reset. The device is restarted and reinitialized, leaving it in the
same state as when the supply voltage is switched on.
Parameter
None
Acknowledgment
’S’ (start signal)
Code recognition
Command
’CC’
Description
Detects an unknown bar code and outputs number of digits, code type, and code in-
formation to the interface, without storing the bar code in the parameter memory.
Parameter
None
Acknowledgment
’xx yyyy zzzzzz’
xx
Code type of the read code
’01’
2/5 Interleaved
’02’
Code 39
’03’
Code 32
’06’
UPC (A, E)
’07’
EAN
’08’
Code 128, EAN 128
’10’
EAN Addendum
’11’
Codabar
’12’
Code 93
’13’
GS1 DataBar OMNIDIRECTIONAL
’14’
GS1 DataBar LIMITED
’15’
GS1 DataBar EXPANDED
yy
Number of digits of the read code
zzzzzz
Contents of the decoded label. A ↑ appears if the label was not cor-
rectly read.