Installation and mounting
Leuze electronic GmbH + Co. KG
AMS 307
i
19
TNT
35/7-2
4V
Aligning the laser light spot with the center of the reflector
The laser light spot has to be aligned so that it always hits the center of the opposing reflector,
both at close range as well as at the maximum measurement distance. To align, use the two
M5 Allen screws ("A" in Figure 5.2). When aligning, please ensure that the knurled nut and
the lock nut ("B" in Figure 5.2) are opened wide.
Attention!
To prevent the laser measurement system from moving out of alignment during continuous
operation, subsequently hand-tighten the knurled nut and counterlock with the nut with WAF4
hexagon socket ("B" in
). Knurled nut and nut must not be tightened until alignment
has been completed.
Attention!
The device must not be opened. Failure to comply will render the guarantee void. Warranted
features cannot be guaranteed after the device has been opened.