Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
AMS 307
i
11
TNT
35/7-2
4V
3
Fast commissioning / operating principle
Note!
Below you will find a short description for the initial commissioning of the AMS 307
i
. Detailed
explanations for the listed points can be found throughout the handbook.
3.1
Mounting the AMS 307
i
The AMS 307
i
and the corresponding reflector are mounted on two mutually opposing, plane-
parallel, flat walls.
Figure 3.1: Schematic illustration of mounting
Attention!
For error-free position measurement, there must be an unobstructed line-of-sight between
the AMS 307
i
and the reflector.
3.1.1
Mounting the device
The laser is mounted using 4 screws (M5).
Alignment is performed using 2 adjustment screws. Adjust so that the laser light spot is posi
-
tioned at the center of the reflector. The alignment is secured with the knurled nut and locked
with the M5 nut.
Detailed information can be found in Chapter 5.2 and Chapter 5.3.
3.1.2
Mounting the reflector
The reflector is mounted using 4 screws (M5). The reflector is angled using the spacer
sleeves included. Incline the reflector by approx. 1°.
Detailed information can be found in Chapter 6.4.