![Leuze electronic SD4R 14 Connecting And Operating Instructions Download Page 56](http://html1.mh-extra.com/html/leuze-electronic/sd4r-14/sd4r-14_connecting-and-operating-instructions_1884032056.webp)
Technical data
56
SOLID-4
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
11.1.4
SD4T Transmitter signal input
Table 11.1-4:
Transmitter, signal input
11.1.5
SD4R-E Receiver signal inputs/outputs
Transmitter
Class
Wavelength
Power
Light-emitting diodes in acc. with
EN 60825-1:1994 + A1:2002 + A2:2001
1
950 nm
< 50µW
Synchronization
Optical between transmitter and receiver
Safety class (IEC EN 61140):
III
Type of protection
IP65*
Ambient temperature, operation
0 ... 55 °C
Ambient temperature, storage
-25 ... 70 °C
Relative humidity
15 ... 95 %
Vibration fatigue limit
5 g, 10 - 55 Hz in acc. with IEC/EN 60068-2-6
Resistance to shock
10 g, 16 ms in acc. with IEC/EN 60068-2-29
Dimensions
See dimensional drawings and tables
Chapter 11.2
Weight
See table, Chapter 11.2
Pin4:
Test input
Input: Contact or transistor against 24 V DC
0 V or free = test
current load: 20 mA max.
Pin1:
Start/restart button
Input: Contact (normally open) against 24 V DC
current load: 15 mA max.
Collective malfunction/
dirt signal
Output: pnp: Typical 22 V DC switching, max. 80 mA
Pin3:
EDM (contactor
monitoring)
Input: Contacts (normally closed) against 0 V
current load: 15 mA max.
Without EDM
Connection to 24 V DC
Pin4:
With RES
Input: 24 V DC
Without RES
Jumper to Pin1
Table 11.1-5:
Receiver, machine interface, status and control signals
*)
Without additional measures the devices are not suited for outdoor use.
Table 11.1-3:
General system data