Electrical connection
Leuze electronic
SOLID-4
39
T
N
T
35/
7-
24V
DEUTSCH
ENGLISH
FRANÇAIS
IT
ALIANO
ESPAÑO
L
NEDERLANDS
7.1.2.1
Transmission channel selection
The polarity of the power supply from Pin2 and Pin7 determines the selected optical
transmission channel.
If 24 V DC is present on Pin2 and 0 V on Pin3, transmission channel 1 is selected. If 0 V is
present on Pin2 and 24 V DC on Pin7, transmission channel 2 is selected.
Note!
Make sure that you select the same transmission channel for both transmitter and receiver.
For optimum shielding, connecting cables with which the shield is routed on the knurled nut
of the housing coupling must be used (suitable cables are listed under accessories in
Chapter 12.4).
Pin
Color
Assignment
Function
1
White
Input:
Start/restart
Signal output:
Weak signal/
error
Start/restart normally open contacts
against 24 V DC
Weak signal/error:
24 V DC light reception, strong,
0 V light reception weak or error
2
Brown
Supply voltage
24 V DC for TC 1 and 0 V for TC 2
3
Green
Input:
Operating
mode/feedback
circuit, EDM
Contactor monitoring (EDM):
24 V DC: Without EDM
0 V: With EDM and FC closed
High impedance: With EDM and FC open
4
Yellow
Input:
Operating mode
Start/restart interlock
(RES):
24 V DC: With RES
Jumper to Pin1: Without RES (note: signal
output remains functional)
5
Gray
Output
OSSD1, transistor switching output
6
Pink
Output
OSSD2, transistor switching output
7
Blue
Supply voltage
0 V for TC 1 and 24 V DC for TC 2
8
Red
Device internally
wired on
housing
Functional earth
Mounting
plug housing
Braided
shield
Shield
Functional earth
Table 7.1-2:
SD4R-E Receiver connection assignment