6.2
Mounting notes
Special notes on mounting a SOLID-4 Safety Light Curtain for
point of operation
guarding
:
➢
Calculate the safety distance according to the formula in Chapter 6.1.1.
➢
Ensure that it is impossible to reach under, over, around or walk behind the Safety Light
Curtain.
➢
Observe the maximum distance between machine table and protective field of 75 mm,
with reference to a table height of 750 mm. If this is not possible because the safety
distance is too big, a mechanical barrier must be provided.
➢
Observe the minimum required distance to reflective surfaces.
a = Distance [mm]
b = Protective field width [m]
Fig. 6.1-5:
Minimum distances from reflective surfaces as a function of the width of
the protective field
130
b
a