Troubleshooting
52
SOLID-4
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
10
Troubleshooting
The following information is used for rapid troubleshooting in the event of a malfunction.
10.1
What do I do if an error occurs?
If the AOPD shows an error on the display, the machine must be stopped immediately and
checked by an experienced technician. If it is determined that the error cannot be clearly
defined and remedied, your local Leuze office and or the Leuze electronic hotline can
assist.
10.2
Diagnostics
Operational malfunctions often have simple causes that you can remedy yourself. The
following tables will help you do this.
10.2.1
SD4T Transmitter diagnostic
10.2.2
SD4R-E Receiver diagnostics
The receiver displays faults and errors with Fxx codes. All possible codes and correspond-
ing activities are then performed.
Symptom
Activity for removing errors
LED is not lit
Check supply voltage
Check connecting cable
Replace transmitter if necessary
LED1 is lit red
continuously
Hardware error, replace transmitter
LED2 is lit red
continuously
Transmitter in test mode
Check test input, connect to 24 V DC
Table 10.2-1:
Transmitter diagnostics
Code Cause/significance
Activity for removing errors
LEDs and 7-segment displays are not lit 24 V DC supply voltage, check connect-
ing cable,
replace the receiver if necessary
F4
Internal hardware fault
Send the device in
F6*
Short circuit between ground and
OSSD1 or cross circuit
Remove short circuit between ground,
overload or cross circuit; turn supply volt-
age off and on again
F7
OSSD short circuit after VCC or cross
circuit, output 1
Remove short circuit after VCC or cross
circuit; if it occurs again, send the device
in
F8*
Short circuit between ground and
OSSD2 or cross circuit
Remove short circuit between ground,
overload or cross circuit; turn supply volt-
age off and on again
*)
Locking error - a system reset is only achieved by switching the supply voltage off and on.