Electrical connection
38
SOLID-4
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
The polarity of the power supply from Pin1 and Pin3 determines the selected optical
transmission channel. If 24 V DC is present on Pin1 and 0 V on Pin3, transmission
channel 1 is selected. If 0 V is present on Pin1 and 24 V DC on Pin3, transmission
channel 2 is selected.
Note!
Make certain you select the same transmission channel for both, for transmitter and
receiver.
For optimum shielding, connecting cables with which the shield is routed on the knurled nut
of the housing coupling must be used (suitable cables are listed under accessories in
Chapter 12.3).
7.1.2
Receiver SD4R-E
Pin
Cable
colors
Assignment
Inputs/outputs
1
Brown
Supply voltage
24 V DC for TC1 and 0 V for TC2
2
White
nc
3
Blue
Supply voltage
0 V for TC1 and 24 V DC for TC2
4
Black
Test in
Test input
Connected to 24 V DC
→
Normal operation
to 0 V or free
→
External test activated
5
Gray
Device internally
wired on hous-
ing
Functional earth
Mounting
plug
housing
Braided
shield
Shield
Functional earth
Table 7.1-1:
Transmitter, connection assignment
Fig. 7.1-2:
SD4R-E 8-pin (view of the pins)
FE