Calculation of the effective protective field height
H
PFE
[mm]
= Effective protective field height
H
PFN
[mm]
= Nominal protective field height (see table 14.8)
A
[mm]
= Total height
B
[mm]
= Additional dimensions for calculation of the effective protective field height (see
C
[mm]
= Value for calculating the effective protective field height (see table 14.9)
Table 14.8:
Dimensions (nominal protective field height), weight and response time
Table 14.9:
Additional dimensions for calculating the effective protective field height
Device type
Transmitter and receiver
Receiver
Dimensions [mm]
Weight [kg] Response time [ms] acc. to resolution
Type
H
PFN
a)
A=H
PFN
+66
b)
14 mm 20 mm 30 mm 40 mm 90 mm
MLC…-600
600
666
0.75
14
12
7
7
3
MLC…-750
750
816
0.90
17
14
8
8
4
MLC…-900
900
966
1.05
20
17
9
9
4
MLC…-1050
1050
1116
1.20
23
19
10
10
4
MLC…-1200
1200
1266
1.35
26
22
12
12
5
MLC…-1350
1350
1416
1.50
30
24
13
13
5
MLC…-1500
1500
1566
1.65
33
26
14
14
6
a) H
PFN
= nominal protective field height = length of the yellow housing part
b) Total height, see figure 14.1
R = resolution
B
C
20 mm
1.5 mm
18 mm
30 mm
13 mm
17 mm