![Leuze electronic MLC 520 Original Operating Instructions Download Page 14](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027014.webp)
Device description
Leuze electronic
MLC 520 EX
14
separated and the cause of the error must be eliminated. Before switching on again, the steps taken before
initial commissioning must be repeated (see chapter 9.1).
The 7-segment display switches to alignment mode when the device has not yet been aligned or when the
protective field has been interrupted (after 5 s). In this case, a fixed beam area from the protective field is
assigned to every segment.
3.3.2 Alignment display
Approximately 5 s after a protective-field interruption, the 7-segment display switches to alignment mode.
In this mode, one third of the total protective field (top, middle, bottom) is assigned to one of the three hori
-
zontal segments and the state of this sub-protective field displayed as follows:
In this mode, one third of the total protective field (Host, Middle Guest, Guest) is assigned to one of the
three horizontal segments and the state of this sub-protective field displayed as follows:
Table 3.4:
Meaning of the alignment display
When the protective field has been free for about 5 s, the device switches back to the display of the oper
-
ating mode.
Segment
Description
Switched on
All beams in the beam area are free.
flashing
At least one, but not all beams in the beam area are free.
Switched off
All beams in the beam area are interrupted.