![Leuze electronic MLC 520 Original Operating Instructions Download Page 18](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027018.webp)
Applications
Leuze electronic
MLC 520 EX
18
Figure 5.3: Access guarding on a transfer path
5.3
Danger zone guarding
Safety light curtains can be used in horizontal arrangement for danger zone guarding - either as stand-
alone device for presence monitoring or as stepping behind protection for presence monitoring e.g. in
combination with a vertically-arranged safety sensor. Depending on the mounting height, resolutions of
40 or 90 mm are used (see chapter 15).
Figure 5.4: Danger zone guarding on a robot