Starting up the device
Leuze electronic
MLC 520 EX
39
If you keep the reset button pressed longer than 4 s:
• Starting at 4 s: the reset request is ignored.
• Starting at 30 s: a +24 V short circuit is assumed on the reset input and the receiver switches to the
interlock state (see chapter 11.1 "What to do in case of error?").