![Leuze electronic MLC 520 Original Operating Instructions Download Page 30](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027030.webp)
Mounting
Leuze electronic
MLC 520 EX
30
Figure 6.9: Mounting directly on the machine table
6.3
Mounting accessories
6.3.1 Deflecting mirror for multiple-side guarding
For multiple-side guarding, redirecting the protective field with one or two deflecting mirrors is economical.
To do this, Leuze electronic supplies
• the UM60 deflecting mirror for mounting on the machine in various lengths (see table 15.5)
• suitable BT-UM60 swivel mounts
• UMC-1000-S2 … UMC-1900-S2 deflecting mirror columns with spring-damped base for free-stand
-
ing floor mounting
The range is reduced by approx. 10 % per deflection. A laser alignment aid with red light laser is recom
-
mended for the alignment of transmitter and receiver (see chapter 8.3 "Aligning of deflecting mirrors with
Note that the distance between the transmitter and the first deflecting mirror cannot be larger than 3 m.
WARNING
Impairment of the protective function due to reflections on the machine table!
Make sure that reflections on the machine table are prevented reliably.
After mounting and every day after that, check the detection capability of the safety sensor in the entire
protective field using a test rod (see figure 9.1).