![Leuze electronic MLC 520 Original Operating Instructions Download Page 43](http://html1.mh-extra.com/html/leuze-electronic/mlc-520/mlc-520_original-operating-instructions_1884027043.webp)
Test
Leuze electronic
MLC 520 EX
43
Table 9.2:
Checklist – regular function test by trained operators/persons
Test at least:
Yes
No
Are safety sensor and connectors securely mounted and free of obvious signs of dam
-
age, changes or tampering?
Were obvious changes made to access or entry possibilities?
Test the effectiveness of the safety sensor:
• The LED 1 on the safety sensor must illuminate green (see chapter "").
• Interrupt an active beam or the protective field (see figure 9.1) with a suitable,
opaque test object:
Figure 9.1: Checking the protective field function with test rod (only for safety light cur
-
tains with a resolution of 14 to 40 mm)
Does the OSSD LED on the receiver illuminate constantly red while the protective field is
interrupted?
When possible, test during running operation:
Yes
No
Protective device with approach function: during machine operation, the protective field
is interrupted with the test object – are the obviously dangerous machine parts stopped
without noticeable delay?
Protective device with presence detection: the protective field is interrupted with the test
object – does this prevent operation of the obviously dangerous machine parts?