Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
63
8.7.3
Module 12 – Multi-label
PROFINET-IO module identifier
Module ID: 1012
Submodule ID: 1
Description
The module permits the definition of multiple bar codes with a different number of digits and/or code types
in the reading gate and provides the necessary input data.
Parameter
Tab. 8.9:
Parameters for module 12
Parameter
Description
Addr. Data type
Value
range
Default
Minimum num-
ber of bar codes
Minimum number of different bar codes
scanned for per reading gate.
0
UNSIGNED8 0 … 64
1
Maximum num-
ber of bar codes
Maximum number of different bar codes
scanned for per reading gate. Only if this
number of bar codes has been reached,
the reading gate is terminated prema-
turely.
1
UNSIGNED8 0 … 64
1
Parameter length
2 bytes
Input data
Tab. 8.10:
Input data for module 12
Input data
Description
Addr. Data type
Value
range
Initial
value
Number of de-
coding results
Number of decoding results which have
not been fetched.
0
UNSIGNED8 0 … 256
0
Input data length
1 byte
Output data
None
This module is used to set the maximum and minimum number of bar codes which are to be decoded
within a reading gate.
If parameter "minimum number of bar codes" = 0, it is not taken into account at the decoder control. If it is
not equal to 0, this means that the bar code reader expects a number of labels within the set range.
If the number of decoded bar codes is within the set limits, no additional "No Reads" are output.
NOTICE
When using this module, the ACK mode should be activated (see chapter 8.7.1 "Module 10 –
Activations", "Mode" parameter). Otherwise there is a risk of losing decoding results if the con-