Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
72
Output data
None
8.8.8
Module 35 – Bar code length
PROFINET-IO module identifier
Module ID: 1035
Submodule ID: 1
Description
The module defines input data for the communication of the length of the currently output bar code.
Parameter
None
Input data
Tab. 8.21:
Input data for module 35
Input data
Description
Addr. Data type
Value
range
Initial value
Bar code length Length/duration of the currently output
bar code, beginning with the code po-
sition specified in module 35 in 1/10
degrees.
0 … 1 UN-
SIGNED16
1 … 900
[1/10 de-
grees]
1 [1/10 de-
grees]
Input data length
2 byte consistent
Output data
None
8.8.9
Module 36 – Scans with information
PROFINET-IO module identifier
Module ID: 1036
Submodule ID: 1
Description
The module defines input data for the communication of the calculated number of scans which provided in-
formation contributing to the result of the bar code.
Parameter
None
Input data
Tab. 8.22:
Input data for module 36
Input data
Description
Addr. Data type
Value range
Initial
value
Scans with information per bar
code
See above
0 … 1 UN-
SIGNED16
0 ,,, 65535
0
Input data length
2 byte consistent
Output data
None