Starting up the device - Configuration
Leuze electronic GmbH + Co. KG
BCL 248i
107
Parameter
Description
Addr. Data type
Value range
Default
multiScan slave
node 20
IP address node 20
135
IP_ADDRESS
0.0.0.0
Parameter length
150 bytes
Input data
None
Output data
None
Data format of the IP_ADDRESS
The IP address is entered as a string in the usual IP-V4 notation, e.g., 192.168.0.1. In addition, it is permis-
sible to enter a 0 for the default setting.
IP_ADDRESS = 0 means that the node is deactivated, i.e., the entry is ignored. The slave enable parame-
ter is automatically set according to the IP address setting during the PNIO configuration phase.
8.15.6 Module 102 – multiScan slave addresses 2
PROFINET-IO module identifier
Module ID: 1102
Submodule ID: 1
Description
Additional module for the configuration of the slave addresses for slaves 21-32.
Parameter
Parameter analogous to module 101.
Parameter length
180 bytes
Input data
None
Output data
None
8.16
Example configuration: Indirect activation via the PLC
8.16.1 Task
Reading of a 10-digit code in 2/5 Interleaved format
Activation of the BCL 248i via the PLC
Code sample
Code 2/5 Interleaved 10 digits with check digit