Mounting
Leuze electronic GmbH + Co. KG
BCL 248i
29
5.2.2
Mounting with BT 56 or BT 56-1 mounting device
Mounting with the mounting device is intended for rod mounting.
Order guide: see chapter 14.4 "Accessories – mounting systems"
Ä
Mount the mounting device on the rod with the clamp profile (system-side).
Ä
Mount the device on the mounting device using the fastening grooves.
ð
Max. tightening torque of the fastening screws: 1.4 Nm
5.2.3
Mounting with BT 300-1 mounting device
Mounting with the mounting device is intended for rod mounting (10 – 16 mm).
Order guide: see chapter 14.4 "Accessories – mounting systems"
Ä
Mount the mounting device on the rod with the clamp profile (system-side).
Ä
Mount the device on the mounting device (included with delivery) using the fastening screws.
ð
Max. tightening torque of the fastening screws: 2.5 Nm
5.2.4
Mounting with the BT 300 W mounting bracket
Mounting with the BT 300 W mounting bracket is intended for wall mounting.
Order guide: see chapter 14.4 "Accessories – mounting systems"
Ä
Mount the mounting bracket on the system side with M4 fastening screws (not included in delivery con-
tents).
Ä
Mount the device to the mounting bracket (included in delivery) with M4 fastening screws.
ð
Max. tightening torque of the fastening screws: 2.5 Nm
5.3
Selecting a mounting location
NOTICE
The size of the bar code module influences the maximum reading distance and the width of the
reading field.
Ä
When selecting a mounting location and/or the bar code label, take into account the different
reading characteristics of the bar code reader with various bar code modules.
NOTICE
Observe when choosing the mounting location!
Ä
Maintain the permissible environmental conditions (humidity, temperature).
Ä
Avoid possible soiling of the reading window due to liquids, abrasion by boxes, or packaging
material residues.
Ä
Ensure that there is the lowest possible chance of damage to the bar code reader by me-
chanical collision or jammed parts.
Ä
Avoid possible ambient light influence (no direct sunlight).
In order to select the right mounting location, several factors must be considered:
• Size, orientation, and position tolerance of the bar codes on the objects to be scanned.
• The reading field of the bar code reader in relation to the bar code module width.
• The resulting minimum and maximum reading distance from the respective reading field with the re-
spective module width (see chapter 13.2 "Reading fields").
• alignment of the bar code reader for avoiding reflections.
• Distance between bar code reader and host system with respect to the interface.
• The correct time for data output. The bar code reader should be positioned in such a way that, taking
into consideration the time required for data processing and the conveyor belt speed, there is sufficient
time to e.g. initiate sorting operations on the basis of the read data.
• The display elements such as LEDs should be highly visible.
• For configuring and commissioning with the webConfig tool, the HOST interface should be easily ac-
cessible.