6. FUNCTIONS
54
6-13-7 AUTO POWER-OFF
Setting
the “
AUTO POWER- OFF
”.
fter selecting the item by pressing
◄/► key, press ENTER to register the setting.
Note:
When “
YES
” is selected, if no key is pressed for about 5 minutes, the machine turns off
automatically.
6-13-8 DEFAULT VALUE OF
“PITCH LENGTH”
Setting the default value of
“
PITCH LENGTH
.
”
Note:
The default value is set initially as “
TUBE = 20mm and TAPE = 10mm
” at our factory.
After setting the desirable value by pressing
▲/▼/
◄/►
key or Ten key,
press ENTER to register the setting.
Note
:
If you press the DELET , the value is initialized to the factory default value.
6-13-9 DEFAULT VALUE OF
“REPEAT”
Setting the default value of
“
REPEAT
.
”
Note:
The default value is set initially as “
TUBE = 2pcs. and TAPE = 1pcs.
” at our factory.
After setting the desirable value by pressing
▲/▼/
◄/►
key or Ten key,
press ENTER to register the setting.
Note
:
If you press the DELET , the value is initialized to the factory default value.
Setting range
:
“Tube”
=
10.0
~
60.0mm
,
“Tape”
=
4.0
~
60.0mm
[ A U T O P O W E R - O F F ]
Y E S
N O
[ P I T C H L E N G T H ]
T U B E =
2 0 . 0
m m
T A P E = 1 0 . 0 m m
Setting range
:
1
~
300pcs.
[ R E P E A T ]
T U B E =
2
P C S
T A P E = 1 P C S
Summary of Contents for MAX LM-550A/PC A11
Page 1: ......