Selection tables
Notes on the selection tables
The selection tables represent the available combinations of gearbox, number of stages, ratio
and motor for the mounting position M1. They only serve as a rough overview.
The following legend shows the layout of the selection tables:
Example
Explanation
Inverter power supply 400 V, self-ventilated motors
Voltage of inverter mains connection, motor cooling type
2 kW
Rated motor power
Inverter operation
Geared motor
Number of
stages
M
2
n
2
c
M
2,max
n
2,th
J
i
g500-
m850-
z
m
Nm
rpm
Nm
rpm
kgcm
2
kg
15.0
1212
3.9
46.0
1056
7.402
3.267
H140
120S40
2
11
16.0
1181
2.9
47.0
970
7.025
3.354
H100
120S40
2
10
16.0
1169
5.8
48.0
915
8.030
3.389
H210
120S40
2
13
21.0
884
3.3
63.0
828
7.036
4.480
H140
120S40
2
11
Mass
Number of gear stages
Motor product name
Gearbox product name
Ratio
Moment of inertia
With feedback, without brake
Max. permissible output speed in S1 operation
Max. permissible acceleration torque
Dependent on inverter
Load capacity of the gearbox
c is the ratio of permissible rated torque of the gearbox to the rated torque of the motor (converted to the driven shaft).
c must always be higher than the application factor detected for the application k.
=
>
´ ´ h
2,zul
1,N
Getr
M
c
k
M
i
Output speed
Output torque
Technical data
Selection tables