Ventilation
No ventilation is required for the gearboxes g500-H45 … H210.
The gearbox g500-H210 can optionally be fitted with ventilation units.
From g500-H320 onwards, the gearboxes are supplied with ventilation units as
standard.
Gearbox in combined mounting position
To reduce the number of different versions, the gearboxes can also be ordered with combined
mounting positions:
•
g500-H100 ... H450 in mounting position M1/5/6 (AEF)
In these gearboxes, the lubricant amount has been optimised for the use in
different mounting positions. If required, the breather elements are loosely
enclosed and must be mounted before commissioning depending on the
mounting position.
NOTICE
▶
For gearboxes with ventilation, a gap of at least 30 mm has to be observed to the machine
wall on the corresponding gearbox side.
Information on project planning
Final configuration
Ventilation
31