Electrical installation
Power terminals
Connection to the DC bus (+U
G
, −U
G
)
112
EDKCSDX064 DE/EN/FR 4.0
L3
N
L1
L2
Z1
K1
L1
L2
L3
PE
X21
+UG
+UG +UG
-UG
-UG
-UG
PE
PE
PE
X22
X23
Off
On
+UG
BR1
BR0
M
3~
R
T1
T2
X6
...
J
2
6
K1
0
U
V
W PE
X24
BD1 BD2
X25
X7
"
"
+
"
"
+UG +UG
-UG
-UG
PE
PE
X23
M
3~
R
J
2
6
0
U
V
W PE
X24
BD1 BD2
X25
X7
+
"
"
"
"
F4
F1...F3
"
"
ECSxS/P/M/A...
ECSxE...
ECSxS/P/M/A...
ECSXA011
Fig. 5−2
Power system: ECSxE power supply module with ECSxS/P/M/A axis modules
HF−shield termination by large−surface connection to functional earth (see
Mounting Instructions for ECSZS000X0B shield mounting kit)
Twisted cables
K1
Mains contactor
F1 ... F4
Fuse
Z1
Mains choke / mains filter, optional
J
KTY thermal sensor of the motor
System cable for feedback˘