Commissioning and operation
Before switching on
6
l
23
BA 11.5032−EN 3.0
6
Commissioning and operation
(
Stop!
Commissioning of the drive only by qualified staff!
6.1
Before switching on
Check:
ƒ
Is the mechanical fixing o.k.?
ƒ
Are the electrical connections o.k.?
ƒ
Are all rotating parts and surfaces that may become hot protected against contact?
ƒ
For gearboxes with breathing:
– Is the plug removed from the breather screw?
)
Note!
Rear−mounted gearboxes must have separate ventilation,
^
Operating
Instruction of the gearbox!
6.2
During operation
(
Stop!
During running−in, raised temperatures may occur over a period of 2 − 8 hours.
ƒ
During operation, check the drive periodically and take special care of:
– unusual noises or temperatures,
– leakages,
– loose fixing elements,
– the condition of the electrical cables.
ƒ
If any interference should occur, proceed according to the troubleshooting list in
chapter 8. If the interference cannot be eliminated, please contact the Lenze Service.