Troubleshooting and fault elimination
8-2
UOMu_^MVMO
8.1.3
Maloperation of the drive
Maloperation
Possible causes
Motor does not rotate
D
DC-bus voltage too low
(red LED is blinking every 0.4 s; message LU is displayed)
D
Controller inhibited
(green LED is blinking, display of the operating module: OFF,
STOP or AS_LC)
D
Setpoint = 0
D
DC braking active
D
Quick-stop function active
D
JOG setpoint activated and JOG frequency = 0
D
Fault is indicated (see chapter 8.3 )
D
Mechanical motor brake is not released
Motor does not rotate
smoothly
D
Defective motor cable
D
Maximum current C022 and C023 too low
D
Motor underexcited or overexcited (check parameter setting)
Current consumption of
motor too high
D
Setting of C016 too high
D
Setting of C015 too low
D
C088 and C091 are not adapted to the motor data.
8.2 Fault analysis using the history buffer
qÜÉ Üáëíçêó ÄìÑÑÉê áë ìëÉÇ íç íê~ÅÉ Ñ~ìäíëK qÜÉ Ñ~ìäí ãÉëë~ÖÉë ~êÉ
ëíçêÉÇ áå íÜÉ Üáëíçêó ÄìÑÑÉê áå íÜÉ çêÇÉê çÑ íÜÉáê çÅÅìêêÉåÅÉK
qÜÉ Üáëíçêó ÄìÑÑÉê Ü~ë Q ãÉãçêó äçÅ~íáçåë ïÜáÅÜ Å~å ÄÉ ~ÇÇêÉëëÉÇ
îá~ ÅçÇÉëK
Structure of the history buffer
Code
C0168
Entry
Note
C161 Memory locations 1 Active fault
If the fault is no longer active or has been
acknowledged:
C162 Memory location 2 Last fault
acknowledged:
D
The contents of the memory locations 1-3 will be
saved in a ”higher” location
C163 Memory location 3 Last but one fault
saved in a ”higher” location.
D
The contents of the memory location 4 will be
eliminated from the history buffer and cannot be
C164 Memory location 4 Last but two fault
y
eliminated from the history buffer and cannot be
read any longer.
D
Memory location 1 will be deleted (= no active fault).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com