Commissioning
5-8
UOMu_^MVMO
5.4 Optimisation of the operating
characteristic of the drive
_ó ãÉ~åë çÑ íÜÉ ÑçääçïáåÖ ëÉííáåÖë óçì Å~å áåÑäìÉåÅÉ íÜÉ ÅìêêÉåíI
íçêèìÉ ~åÇ éçïÉê ÅÜ~ê~ÅíÉêáëíáÅ çê íÜÉ ÅçååÉÅíÉÇ ãçíçêK
vçì Å~å ÅÜççëÉ ÄÉíïÉÉå íÜÉ Åçåíêçä ãçÇÉë ÒsLÑJÅÜ~ê~ÅíÉêáëíáÅ
Åçåíêçä ïáíÜ ~ìíç ÄççëíÒ ~åÇ ÒsLÑJÅÜ~ê~ÅíÉêáëíáÅ Åçåíêçä ïáíÜ
Åçåëí~åí s
ãáå
ÄççëíÒK få ÅÜ~éíÉê RKQKN óçì ïáää ÑáåÇ ëçãÉ ãçêÉ
áåÑçêã~íáçå íç ÜÉäé óçì ïáíÜ íÜÉ ëÉäÉÅíáçåK
5.4.1
Select the control mode
Code
Name
Possible settings
IMPORTANT
Lenze Selection
Info
C014
¿
Operating mode
-0-
-0- Linear characteristic V
~
f
d
with
auto boost
-1- Square characteristic V
~
f
d
2
with auto boost
-2- Linear characteristic V
~
f
d
with
constant V
min
boost
-3- Square characteristic V
~
f
d
2
with constant V
min
boost
Control
modes of the
voltage
characteristic
Function
D
Under C014 you can set the control mode and the voltage characteristic.
D
The V/f-characteristic control with auto boost enables a low-loss operation of single
drives with standard three-phase AC motors with load-dependent V
min
boost.